Accueil > Résultat de la recherche


Vos critères

Affiner votre recherche

Type

Laboratoire

Nom

Référence Produit

Commence par ...

Classification 1

Classification 2









ACCUDRAIN EXTERNAL CSF DRAINAGE SYSTEM ACCUDRAIN EVD SYSTEM

Réf. industriel : INS8400     ExhausCode : 01/00834/INS8400 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM ACCUDRAIN NEEDLE SITE THE ACCUDRAIN TM EXTERNAL DRAINAGE SYSTEMS ARE DESIGNED TO EXTERNALLY DRAIN CEREBROSPINAL FLUID (CSF) FROM THE LATERAL VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG IN SELECTED PATIENTS. THE SYSTEMS CONNECT TO A VENTRICULAR OR LUMBAR CATHETER VIA A LUER CONNECTION TO A PATIENT LINE AND ULTIMATELY TO A DRAINAGE BAG. THE PATIENT LINE IS CONNECTED TO A GRADUATED BURETTE THAT IS THEN CONNECTED TO THE DRAINAGE BAG. CSF CAN BE COLLECTED AND MEASURED IN THE BURETTE AND SUBSEQUENTLY EMPTIED INTO THE DRAINAGE BAG BY OPENING THE STOPCOCK PLACED IN LINE BETWEEN THE BURETTE AND THE DRAINAGE BAG. AN ANTIMICROBIAL VENT IS INCLUDED IN THE BURETTE CAP. THIS ANTIMICROBIAL VENT ALLOWS AIR TO ENTER THE BURETTE TO FACILITATE DRAINAGE FROM THE BURETTE TO THE DRAINAGE BAG WHILE PROTECTING SYSTEM FROM MICROBIAL CONTAMINATION. THE ANTIMICROBIAL VENT USED ON THE ACCUDRAINTM SYSTEMS WILL ALLOW BETTER DRAINAGE OF THE CSF TO THE DRAINAGE BAG AND WILL RESIST OCCLUSION AFTER CONTACT WITH CSF.

Réf. industriel : SP0235     ExhausCode : 01/00834/SP0235 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM ACCUDRAIN SPECIAL SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, UBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR-WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0233     ExhausCode : 01/00834/SP0233 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM ACCUDRAIN SPECIAL SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, UBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR-WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0222     ExhausCode : 01/00834/SP0222 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSUE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING.

Réf. industriel : SP0234     ExhausCode : 01/00834/SP0234 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALUS HUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES OF THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR-WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OF LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARIFY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0238     ExhausCode : 01/00834/SP0238 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0219     ExhausCode : 01/00834/SP0219 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0218     ExhausCode : 01/00834/SP0218 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0216     ExhausCode : 01/00834/SP0216 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0215     ExhausCode : 01/00834/SP0215 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0214     ExhausCode : 01/00834/SP0214 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ACCUDRAIN® EXTERNAL CSF DRAINAGE SYSTEM THE ACCUDRAIN™ EXTERNAL CSF DRAINAGE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING. MONITORING OF INTRACRANIAL PRESSURE (ICP) IS USUALLY PERFORMED IN SELECTED PATIENTS WITH SEVERE HEAD INJURY, SUBARACHNOID HEMORRHAGE, REYES SYNDROME OR SIMILAR ENCEPHALOPATHIES, HYDROCEPHALUS, HYDROCEPHALIC SHUNT INFECTIONS, INTRACRANIAL HEMORRHAGE AND PRE AND/OR POST OPERATIVE MONITORING. COMMON FEATURES TO THE SYSTEM INCLUDE A CLOSED STERILE FLUID PATH, CALIBRATED 75ML GRADUATED BURETTE STOPCOCK, 700ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, TWO NEEDLELESS SAMPLING SITES, A PATIENT STOPCOCK, A FOUR WAY HIGH FLOW BURETTE STOPCOCK, CORD SUSPENSION, RED BURETTE HEIGHT INDICATOR, AND INTEGRAL ATTACHMENT FEATURE. A LINE LEVEL OR LASER DEVICE CAN BE ATTACHED. THE TRANSPARENT GRADUATED BURETTE PROVIDES VISUALIZATION OF THE FLOW AND CLARITY OF THE CSF, AND ALLOWS FOR VOLUMETRIC READINGS TO BE MADE PRIOR TO FLUID ENTERING THE DRAINAGE BAG.

Réf. industriel : SP0213     ExhausCode : 01/00834/SP0213 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

CODMAN CODMAN EXTERNAL DRAINAGE VENTRICULAR CATHETER SET

Réf. industriel : 82-1705     ExhausCode : 01/00032/821705 Dernière mise à jour : 04/02/2016

CODMAN
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

CODMAN LUMBAR DRAINAGE CATHETER KIT II

Réf. industriel : 821707     ExhausCode : 01/00050/821707 Dernière mise à jour : 12/07/2016

JOHNSON & JOHNSON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

ENSEMBLE DE DRAINAGE LOMB. EXT. AV SAC VIDANGEABLE DE 700 ML

Réf. industriel : 910420     ExhausCode : 01/00834/910420 Dernière mise à jour : 28/03/2017

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC EXTERNAL CSF DRAINAGE SYSTEM POLE MOUNT, PRESS. MONIT. SYS.THE EXTERNAL CSF DRAINAGE SYSTEMS PROVIDE A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEMS ARE USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, FLUID INJECTION, CSF SAMPLING AND INTRACRANIAL PRESSURE MONITORING. COMMON FEATURES INCLUDE A CALIBRATED 50 ML GRADUATED BURETTE, 700 ML DRAINAGE BAG, ANTI-MICROBIAL HYDROPHOBIC VENT, NEEDLELESS SAMPLING/ASPIRATION SITES AND PRESSURE MONITORING GREEN STRIBED TUBING.

Réf. industriel : INS8601     ExhausCode : 01/00834/INS8601 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC PLUS™ EXTERNAL CSF DRAINAGE SYSTEMS HERMETIC PLUS SPECIAL THE HERMETIC PLUS EXTERNAL CSF DRAINAGE SYSTEM PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. THIS SYSTEM INCLUDES A GREEN STRIPED PATIENT LINE AND NEEDLESS INJECTION SITE, BUT DOES NOT CONTAIN THE Y-SAMPLING SITE FROM THE PATIENT LINE.

Réf. industriel : SP0204     ExhausCode : 01/00834/SP0204 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC PLUS™ EXTERNAL CSF DRAINAGE SYSTEMS HERMETIC PLUS,EVD SYSTEM THE HERMETIC PLUS EXTERNAL CSF DRAINAGE SYSTEM PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. THIS SYSTEM INCLUDES A GREEN STRIPED PATIENT LINE WITH ANTI-REFLUX VALVE, NEEDLELESS INJECTION SITES, DRAINAGE BAG, BURETTE, AND POLE MOUNTED SUPPORT PANEL. IT DOES NOT CONTAIN A Y-SAMPLING SITE OR DISTAL STOPCOCK FROM PATIENT LINE.

Réf. industriel : SP0211     ExhausCode : 01/00834/SP0211 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC PLUS™ EXTERNAL CSF DRAINAGE SYSTEMS HERMETIC SPECIAL-NO Y SITE THE HERMETIC PLUS EXTERNAL CSF DRAINAGE SYSTEM PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEM IS USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. THIS SYSTEM INCLUDES A GREEN STRIPED PATIENT LINE WITH ANTI-REFLUX VALVE, NEEDLELESS INJECTION SITES, DRAINAGE BAG, BURETTE, AND POLE MOUNTED SUPPORT PANEL.

Réf. industriel : SP0201     ExhausCode : 01/00834/SP0201 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC PLUS™ EXTERNAL CSF DRAINAGE SYSTEMS THE HERMETIC PLUS EXTERNAL CSF DRAINAGE SYSTEMS PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEMS ARE USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, FLUID INJECTION, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING.

Réf. industriel : INS8302     ExhausCode : 01/00834/INS8302 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC PLUS™ EXTERNAL CSF DRAINAGE SYSTEMS THE HERMETIC PLUS EXTERNAL CSF DRAINAGE SYSTEMS PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEMS ARE USED TO DRAIN CEREBROSPINAL FLUID (CSF) FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A DRAINAGE BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, FLUID INJECTION, CSF SAMPLING AND INTRACRANIAL PRESSURE (ICP) MONITORING.

Réf. industriel : INS8301     ExhausCode : 01/00834/INS8301 Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

HERMETIC™ II EXTERNAL CSF DRAINAGE MANAGEMENT THE HERMETIC II EXTERNAL CSF DRAINAGE MANAGEMENT SYSTEM PROVIDES A STERILE FLUID PATH RESISTANT TO MICROBIAL PARTICLES. THE SYSTEM IS USED TO DRAIN CSF FROM THE VENTRICLES OF THE BRAIN OR THE LUMBAR SUBARACHNOID SPACE TO A COLLECTION BAG. SYSTEM COMPONENTS FACILITATE CSF DRAINAGE, FLUID INJECTION, CSF SAMPLING AND INTRACRANIAL PRESSURE MONITORING.

Réf. industriel : NL8508300N     ExhausCode : 01/00834/NL8508300N Dernière mise à jour : 27/12/2018

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT BECKER EDMS II

Réf. industriel : 26040     ExhausCode : 01/00169/26040 Dernière mise à jour : 01/09/2017

MEDTRONIC
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT CATHETER LOMBAIRE F5

Réf. industriel : 9MD522     ExhausCode : 01/00834/9MD522 Dernière mise à jour : 28/03/2017

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT CATHETER VENTRICULAIRE DROIT

Réf. industriel : 951102A     ExhausCode : 01/00834/951102A Dernière mise à jour : 28/03/2017

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DE DRAINAGE LOMBAIRE EXTERNE AV EDS3

Réf. industriel : 821738     ExhausCode : 01/00578/821738 Dernière mise à jour : 23/11/2017

DEPUY SYNTHES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DE DRAINAGE LOMBAIRE EXTERNE II

Réf. industriel : 821707     ExhausCode : 01/00013/821707 Dernière mise à jour : 29/08/2017

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DE DRAINAGE LOMBAIRE EXTERNE II

Réf. industriel : 821707     ExhausCode : 01/00032/821707 Dernière mise à jour : 11/07/2016

CODMAN
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DRAINAGE EXTERNE LCR + CATHE VENTR

Réf. industriel : 82-1730     ExhausCode : 01/00013/821730 Dernière mise à jour : 16/07/2015

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DRAINAGE VENTRICULAIRE EXT EDSII

Réf. industriel : 821720     ExhausCode : 01/00032/821720 Dernière mise à jour : 11/07/2016

CODMAN
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DRAINAGE VENTRICULAIRE EXT EDSII

Réf. industriel : 821720     ExhausCode : 01/00050/821720 Dernière mise à jour : 10/01/2016

JOHNSON & JOHNSON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

KIT DRAINAGE VENTRICULAIRE EXT EDSII

Réf. industriel : 821720     ExhausCode : 01/00013/821720 Dernière mise à jour : 16/07/2015

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

RESERVOIR UNISHUNT 05-09CM / 090CM

Réf. industriel : 828532     ExhausCode : 01/00013/828532 Dernière mise à jour : 16/07/2015

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

RESERVOIR UNISHUNT 05-09CM / 102CM

Réf. industriel : 828542     ExhausCode : 01/00013/828542 Dernière mise à jour : 16/07/2015

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

RESERVOIR UNISHUNT 09-14CM / 102CM

Réf. industriel : 828543     ExhausCode : 01/00013/828543 Dernière mise à jour : 16/07/2015

ETHICON
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

SET DRAINAGE VENTRICULAIRE STD IVDS

Réf. industriel : 910412     ExhausCode : 01/00834/910412 Dernière mise à jour : 28/03/2017

INTEGRA LIFESCIENCES SERVICES
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

SYSTEME DE DRAINAGE EXTERNE EDS III AVEC CATHETER VENTRICULAIRE

Réf. industriel : 821730     ExhausCode : 01/00032/821730 Dernière mise à jour : 11/07/2016

CODMAN
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

SYSTEME DE DRAINAGE EXTERNE SANS CATHETER VENTRICULAIRE EDSIII

Réf. industriel : 821731     ExhausCode : 01/00032/821731 Dernière mise à jour : 11/07/2016

CODMAN
VOIR LA MONOGRAPHIE

Demande d'infos

ou de devis

CONTACT

Tel 01 80 91 99 08

info@exhausmed.com

Nos locaux :
62 bis avenue Joffre
94100 Saint-Maur des Fossés

SUIVEZ-NOUS SUR

S'inscrire à la newsletter