Accueil > INTEGRA LIFESCIENCES SERVICES > INTEGRA PERITONEAL OPEN-ENDED CATHETER WITH SLITS THE INTEGRA PERITONEAL REFLUX CONTROL CATHETER IS DESIGNED TO DELIVER CSF TO THE PERITONEAL CAVITY WITH MINIMUM FLOW RESISTANCE. THIS CATHETER IS RECOMMENDED FOR USE WITH PRESSURE CONTROL VALVES LOCATED PROXIMALLY IN THE HYDROCEPHALIC SHUNT SYSTEM. THIS CATHETER HAS A SERIES OF SLITS LOCATED ALONG THE CATHETER’S DISTAL SECTION. THE CATHETER IS MADE OF A HIGH DUROMETER SILICONE ELASTOMER WHICH HELPS RESIST KINKING AND OCCLUSION CAUSED BY THE BENDING OR TWISTING OF THE CATHETER. A STRIPE, MADE OF BARIUM SULFATE IMPREGNATED SILICONE ELASTOMER, IS IMBEDDED IN THE WALL OF THE CATHETER. THIS CATHETER PROVIDES FLOW RESISTANCE OF APPROXIMATELY 12MM H2O AT A FLOW RATE OF 23 ML/HR. Retour à la recherche


INTEGRA PERITONEAL OPEN-ENDED CATHETER WITH SLITS THE INTEGRA PERITONEAL REFLUX CONTROL CATHETER IS DESIGNED TO DELIVER CSF TO THE PERITONEAL CAVITY WITH MINIMUM FLOW RESISTANCE. THIS CATHETER IS RECOMMENDED FOR USE WITH PRESSURE CONTROL VALVES LOCATED PROXIMALLY IN THE HYDROCEPHALIC SHUNT SYSTEM. THIS CATHETER HAS A SERIES OF SLITS LOCATED ALONG THE CATHETER’S DISTAL SECTION. THE CATHETER IS MADE OF A HIGH DUROMETER SILICONE ELASTOMER WHICH HELPS RESIST KINKING AND OCCLUSION CAUSED BY THE BENDING OR TWISTING OF THE CATHETER. A STRIPE, MADE OF BARIUM SULFATE IMPREGNATED SILICONE ELASTOMER, IS IMBEDDED IN THE WALL OF THE CATHETER. THIS CATHETER PROVIDES FLOW RESISTANCE OF APPROXIMATELY 12MM H2O AT A FLOW RATE OF 23 ML/HR.

Réf. industriel : NL8501376
ExhausCode : 01/00834/NL8501376
Le produit est-il dans le GHS ?
Pas d'information sur le statut T2A de ce produit
Intitulé normatif 1
Intitulé normatif 2
Intitulé normatif 3
Intitulé normatif 4
Intitulé normatif 5
Intitulé Normatif court
Intitulé Normatif long
Nom de marque                                            INTEGRA PERITONEAL OPEN-ENDED CATHETER WITH SLITS
Classification
Intitulé 1             CATHETER
Intitulé 2             PERITONEALE
Cladimed
Cladimed 1
Cladimed 2
Cladimed 3
Cladimed 4
Cladimed 5
Code Compta (M21)
Stérile
Latex
Usage unique
Exhauscode01/00834/NL8501376
Code UDI
Code EAN

Demande d'infos

ou de devis

Date d'insertion :
06/02/2016
Dernière mise à jour :
03/04/2019
CPAM et matériovigilance:
INTEGRA LIFESCIENCES SERVICES
Adresse :
Immeuble Sequoia 2, 97 Allée Alexandre Borodine 69800 SAINT PRIEST
Politique de transparence
Téléphone du siège :

04 37 47 59 00

Fax du siège :

04 37 47 51 52

Téléphone commandes :

04 37 47 59 10

 
Catalogue de :
INTEGRA LIFESCIENCES SERVICES

CONTACT

Tel 01 80 91 99 08

info@exhausmed.com

Nos locaux :
62 bis avenue Joffre
94100 Saint-Maur des Fossés

SUIVEZ-NOUS SUR

S'inscrire à la newsletter